Shrnutí obsahu

Strany 1 - TI2000 GPU-24

!"#$%&'(#)*"'$%+,!"#$%& '()*#+,-"#& '(./012&3"(+",45-(+&6$7)/8"9&3%#+$&

Strany 2

2-47) Replace thewhite clip back intothe fuse clip. Takecare not to damagethe tabs.8) Completely insertwhite clip in to fuseclip (GENTLY) untilit snap

Strany 3 - LIST OF ILLUSTRATIONS

2-2CHAPTER 3OPERATING LIMITS AND RESTRICTIONSSECTION I. GENERAL3-1. PURPOSEChapter 3 includes all important operating limits and restrictionsthat mus

Strany 4

3-13-4. 120-240 VAC CHARGER AND AC TO DC CONVERTER LIMITSThe unit is designed with a single point AC receptacle for externalpower to operate both the

Strany 5

3-2AC Line Cords Cont. Europe U.K. Old British North AmericanCAUTION Unit will be damaged if unapproved AC power is applied b

Strany 6

3-33-8. CONTINUOUS OUTPUT RATE, 28.5 VDC CONSTANT OUTPUT20 amp hours (with AC power connected)NOTEIf current demand exceeds 20 amps, converter outpu

Strany 7 - Fuse setting (120/

Storage range:-60Co (-76oF) TO +60Co (+140oF)(C0NTINUED ON NEXT PAGE)3-4CAUTIONUnit may be damaged if operated when unit’s cold or heat soaked tempera

Strany 8

3-5WARNING********SHOCK HAZARD POTENTIAL*********Severe injury, or Death, from electrical shock is possible when per-sonnel and/or Turbo Start 2000 ar

Strany 9

3-6CAUTIONUnit damage may occur if inlet and outlet vent ports are obstructedand/or cooling air flow is restricted.3-13. UNIT OPERATION DURING AIRCRA

Strany 10 - Fuse Setting Procedures

3-7CHAPTER 4OPERATING PROCEDURESSECTION I. UNIT OPERATION4-1. GENERALCorrect operation of the TI2000GPU-24 (Turbo Start 2000) includesboth pre-use a

Strany 11 - CHAPTER 3

4-1SECTION II. OPERATING PROCEDURES4-4. OPERATING PROCEDURESThis section deals with normal procedures, and includes all stepsnecessary to ensure safe

Strany 12 - 32: (5 6285&(

WARNING*******SHOCK HAZARD POTENTIAL*******IMPROPER USE/FAILURE TO FOLLOW INSTRUCTIONS IN OPERATORS MANUAL CANRESULT IN UNIT FAILURE AND/OR POSSIBLE I

Strany 13

that cooling fan is functioning.4-2CAUTIONREMEMBER,when the AC line cord is plugged in, the unit must be placedin the horizontal position to allow the

Strany 14

starting procedure as specified in aircraft operators manual.5. REMOVING DC POWER SUPPLY FROM AIRCRAFTa. Remove DC power cable GPU connector from air

Strany 15 - (C0NTINUED ON NEXT PAGE)

(if necessary).4-44-8 28.5 VDC GROUND POWER (WITH 120/240 VAC POWER) SYSTEM LOW POWERDEMAND (20 amps or less).1. TRANSPORT UNIT - The Turbo Start

Strany 16 - Horizontal only

indicating power cell state of charge and cooling fan is operating.4-5CAUTIONUnit may overheat if cooling fan fails.Do not operate if cooling fan fail

Strany 17

4-6SECTION III.FUNCTIONAL CHECK PROCEDURES4-10. FUNCTIONAL CHECK PROCEDURESThis section deals with normal functional check procedures, and in-cludes

Strany 18 - CHAPTER 4

and cooling fan are operational. Prior to continuing to step 7, theLED status indicator should show a single green bar (last LED bar) toindicate the u

Strany 19 - BEFORE PLUGGING

4−8CHAPTER 5PERFORMANCE DATASECTION 1. INTRODUCTION5-1. PURPOSEThis chapter provides performance data for the TI2000GPU-24 (TurboStart 2 000). Conti

Strany 20 - the unit down horizontally

the ground power support requirements are presented. Wherever practi-cal, data is presented conservatively. However, NO GENERAL CONSERVATISMHAS BEEN

Strany 21

shown in the performance charts do not account for instrument toler-ance differences or inaccuracies.5-6. DEFINITIONS OF ABBREVIATIONSUnless otherwis

Strany 22

5-3 FIGURE 5-2TI2000GPU-24 OUTPUT VOLTAGEOUTPUT VOLTAGEMINUTES46 AMP CONSTANT CURRENT LOAD24201612840010 2030405060

Strany 23

iTABLE OF CONTENTSTITLE PageCHAPTER 1 INTRODUCTION 1-1CHAPTER 2 UNIT DESCRIPTION AND OPERATION 2-1Section I Unit 2-1Section II Description 2-2CHAPTER

Strany 24 - Unit shall be in horizontal

5-4 FIGURE 5-300300600900120015001800210030002700240051015202530************************************************************(+25 C Temp)(-29 C Temp

Strany 25

5-5CHAPTER 6CARE AND MAINTENANCESECTION I. UNIT CARE6-1. GENERAL Although the TI2000GPU-24 (Turbo Start 2000) has been ruggedizedand made weather

Strany 26 - CHAPTER 5

6-1SECTION II.MAINTENANCE6-3. MAINTENANCE OF UNIT - The Turbo Start 2000 is a maintenance-free unit, no repairs are authorized. Warranty will be voi

Strany 27

Chapter 7Push To Test ModificationGeneral Information And Operation7-1. GeneralTHIS MODIFICATION HAS BECOME STANDARD EQUIPMENT FOR EACH OF OURUNITS.

Strany 28

PARAGRAPH INDEX120-240 VAC Charger and AC to DC Converter Limits, 3-424 VDC Ground Power (NO 120 or 240 VAC Power Supply) Engine Startingor DC system

Strany 29 - 46 AMP CONSTANT CURRENT LOAD

PARAGRAPH INDEXIndex, 1-4Maintenance of Unit, 6-3Maximum Output Current, Figure 5-3One (1) Hour Rate, 24 VDC Constant Output, 3-6Operating Limits

Strany 30 - MAXIMUM OUTPUT CURRENT

APPENDIX AOPTIONAL LINE CORDS FOR WORLDWIDE OPERATIONSCOUNTRY VOLTS HZ TESLA PART #Afganistan 220 50 TI25000-004 Old British Lin

Strany 31 - CHAPTER 6

APPENDIX A (Cont.)OPTIONAL LINE CORDS FOR WORLDWIDE OPERATIONSCOUNTRY VOLTS HZ TESLA PART #Ecuador 120 60 TI25000-001 North Amer

Strany 32 - MAINTENANCE

APPENDIX A (Cont.)OPTIONAL LINE CORDS FOR WORLDWIDE OPERATIONSCOUNTRY VOLTS HZ TESLA PART #Laos 220 50 TI25000-001 North America

Strany 33 - Chapter 7

APPENDIX A (Cont.)OPTIONAL LINE CORDS FOR WORLDWIDE OPERATIONSCOUNTRY VOLTS HZ TESLA PART #Romania 220 50 TI25000-003 Cont. Euro

Strany 34

iiCHAPTER 1INTRODUCTION1-1. GENERALThese instructions are for use by the owner/operator. They apply tohandling and operation of the TI2000GPU-24 (T

Strany 35

A-5APPENDIX A (Cont.)UNIVERSAL LINE CORD KIT FOR WORLDWIDE OPERATIONSNOTE: TESLA UNIVERSAL AC LINE CORD KIT, P/N: TI25000-U00, IS FORUNITS ORIGINALLY

Strany 36 - APPENDIX A

1-11-4. INDEXThe index lists, in alphabetical order, every titled paragraph andfigure contained in this manual.1-5. ABBREVIATIONS AND SYMBOLSAbbrevi

Strany 37 - APPENDIX A (Cont.)

Guard from incorrect power source1-21-6. FORMS AND RECORDSNONE REQUIRED.1-7. USE OF WORDS SHALL, SHOULD, AND MAY.Within this technical manual the wo

Strany 38

1-3CHAPTER 2UNIT DESCRIPTION AND OPERATIONSECTION I. UNIT2-1. GENERALThe TI2000GPU-24 (Turbo Start 2000) (Figure 2-1 and 2-2) is a compact, portablea

Strany 39

120 VAC Setting 2-1 240 VAC SettingSECTION II DESCRIPTION2.2. GENERAL SPECIFICATIONSWEIGHTUNIT: 111 lbs (50.39 Kg)DC POWER CABLE: 8.5 l